Envirovalve is an inexpensive
system offering both easy
operation and no heavy
moving parts...
Find More
Use our product selector
to find the the system
that best suits your
needs
Search Now

Activating the envirovalve pollution prevention and control system

The envirovalve drain security system can be controlled and activated at the touch of a button from anwhere.  Below are listed the standard activation methods currently available.  Please do not hesitate to contact us if your preferred method of activation is not listed to discuss your individual requirements.

  • Manual activation of envirovalve systemManual activation

The envirovalve unit comes complete with manual activation as standard.  The unit can only be activated by opening the system cabinet and turning the "on/off" switch within to the "on" position by hand.  The manually operated switch activates the pump, powered by a 12volt d.c. battery, which inflates the bladder, blocking the drain.  Once the bladder reaches its preset pressure the system is sealed and the pump is set to re-pressure the bladder if required.

 

Hard Wired Remote hard wired envirovalve activation

The envirovalve unit can be activated any distance away from the system cabinet using a non powered static volt free switching that is hard wired back to the system cabinet.  Switching can be manual or from some other system such as a fire alarm, ph meter, level controller etc.  The envirovalve unit can also be activated as per standard manual activation.  The unit can only be deactivated locally and requires a battery plus either mains or solar power for operation.

 

 

GSM 

gsm activationThe envirovalve unit can be activated from any distance using a mobile phone to send a text message.  There is no physical connection to the system cabinet.  The envirovalve unit can also be activated as per standard manual activation.  The unit can only be deactivated locally and requires a battery plus either mains or solar power for operation.

 

 

 

 

GSM Telemetry Remote

The envirovalve unit can be activated any distance away from the system cabinet using a gsm telemetry remotemains powered static terminal that transmits an activation signal to the cabinet upon receipt of a (volt free) signal from some other system such as a fire alarm, ph meter, level controller etc.  There is no physical connection to the system cabinet.  The envirovalve unit can also be activated as per standard manual activation.  The unit can only be deactivated locally and requires a battery plus either mains or solar power for operation.